With true double-conversion design, VR 6-10K series provides powerful and overall protection to your sensitive devices. It can accept wider input voltage for harsh environment. It's perfect protection for your precious servers and workstations.
True double-conversion
sensitive lab devices
automatics
controll
servers
Model | ORVALDI 6K (L) RT | ORVALDI 10K (L) RT | ||||
PHASE | 1 phase in/ 1 phase out | |||||
CAPACITY | 6000 VA/6000 W | 10000 VA/10000 W | ||||
INPUT | ||||||
Nominal Voltage | 208/220/230/240 VAC | |||||
Voltage Range |
110-300 VAC @ 0~60% load; 140-300 VAC @ 60~80 % load; 176-300 VAC @ 80~100 % load |
|||||
Frequency Range | 46 ~54 Hz or 56~64 Hz | |||||
Phase | Single phase with ground | |||||
Power Factor | ≧ 0.99 @ 100% Load | |||||
THDi | ≦ 4% @100% load; <6% @ 50% load | |||||
OUTPUT | ||||||
Output Voltage | 208*/220/230/240 VAC | 208*/220/230/240 VAC | ||||
AC Voltage Regulation (Batt. Mode) | ± 1% | |||||
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz | |||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | |||||
Current Crest Ratio | 3:1 (max.) | |||||
Harmonic Distortion | ≦1.5% THD (Linear Load), ≦ 7 % THD (Non-linear Load) | |||||
Transfer Time | AC Mode to Batt. Mode | zero | ||||
Inverter to Bypass | zero | |||||
Waveform (Batt. Mode) | Pure Sinewave | |||||
Overload | AC Mode | 100%~110%: 10 min; 110%~130%: 1 min; >130%: 1 sec | ||||
Battery Mode | 100%~110%: 30 sec; 110%~130%: 10 sec; >130%: 1 sec | |||||
EFFICIENCY | ||||||
AC Mode | 94% | 94% | ||||
Battery Mode | 91% | 91% | ||||
BATTERY | ||||||
Standard Model | Battery Type | 12V/7 Ah | 12V/ 9Ah | |||
Numbers | ||||||
Typical Recharge Time | 9 hours recover to 90% capacity | |||||
Charging Current (Max.) | 1.0A | |||||
Charging Voltage | 218.4 VDC ±1% | |||||
Long-run Model | Battery Type | Depending on applications | ||||
Numbers | 16-20** | |||||
Charging Current (Max.) | 4.0A | |||||
Charging Voltage | (13.65 VDC x battery number) ± 1% | |||||
INDICATORS | ||||||
LCD Panel | UPS status, load level, battery level, input/output voltage, discharge timer, and fault conditions | |||||
ALARM | ||||||
Battery Mode | Sounding every 4 seconds | |||||
Low Battery | Sounding every 2 seconds | |||||
Overload | Sounding twice every second | |||||
Fault | Continuously sounding | |||||
PHYSICAL | ||||||
Standard Model | Dimension, DxWxH (mm) | UPS Unit: 600x438x88 [2U]; Battery Pack: 695x438x88[2U] | UPS Unit: 600x438x88 [2U]; Battery Pack:695x438x88[2U] | |||
Net Weight (kgs) | UPS Unit: 15; Battery Pack: 48 | UPS Unit:18; Battery Pack: 48 | ||||
Long-run Model | Dimension, DxWxH (mm) | 600x438x88 [2U] | 600x438x88[2U] | |||
Net Weight (kgs) | 15 | 18 | ||||
ENVIRONMENT | ||||||
Humidity | 20-90 % RH @ 0- 40°C (Non-condensing) | |||||
Noise Level | Less than 55dB@1Meter | Less than 58dB@1Meter | ||||
MANAGEMENT | ||||||
Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, and MAC | |||||
Optional SNMP | Power management from SNMP manager and web browser |
* Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208 VAC. |
** When using batteries from 16-19, the unit will de-rate according to the formula: P=Prating x N/20 |
*** If the UPS is installed or used in a place where the altitude is above than 1000m, the output must be derated one percent per 100m. |
Product specifications are subject to change without further notice. |