Seria: On-line

With true double-conversion design, Galleon series provides powerful and overall protection to your sensitive devices. It can accept wider input voltage for harsh environment. It's perfect protection for your precious servers and workstaiosn.

Manufacturer: ORVALDI
Product code: V20KL 3/1Phase
ORVALDI V20KL on-line 3p/1p
ORVALDI V20KL on-line 3p/1p
ORVALDI V20KL on-line 3p/1p

Characteristic:

True double-conversion

  • DSP technology guarantees high performance
  • Output power factor 0.8
  • Wide input voltage range (110-300 VAC)
  • Built-in phase auto adapt function simplifies wire installation
  • 50Hz/60Hz frequency converter mode
  • ECO mode operation for energy saving
  • Programmable power management outlets
  • Emergency power off function (EPO)
  • Generator compatible
  • Charger capacity expansion to 8A for long-run models
  • SNMP+USB+RS-232 multiple communications
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery numbers
  • Maintenance bypass available
  • Optional isolation transformer available
  • Active power factor correction mode

List of applications:

Data Center

Talecom centers

Industry

Medical equipment

Technical data:

Model Galleon 3/1-20K (L) Galleon 3/1-20K ISO L
PHASE 3-phase in / 1-phase out
CAPACITY 20000 VA/16000 W 20000 VA/16000 W
INPUT
Nominal Voltage 3 x 400 VAC (3Ph+N)
Voltage Range 305-478 VAC (3-phase) at 100% load ; 190-520 VAC (3-phase) at 50% load
Frequency Range 46~54Hz or 56~64Hz
Power Factor ≧ 0.99 @ 100% Load
THDi < 6% @ 100% load
OUTPUT
Output Voltage 208/220/230/240VAC 104/110/115/120VAC or 208/220/230/240VAC
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≦ 2 % THD (Linear Load) ≦ 5 % THD (Non-linear Load) ≦2 % THD (Linear Load) ≦7% THD (Non-linear Load)
Transfer Time AC Mode to Batt. Mode Zero
Inverter to Bypass Zero
Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY
AC Mode 89% 87%
Battery Mode 87% 83%
BATTERY
Standard Model Battery Type 12 V / 9 Ah
Numbers 20 pcs (18 - 20 pcs adjustable)* x 2 strings N/A
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current (Max.) 2A
Charging Voltage 273 VDC ± 1% (Based on 20pcs batteries)
Long-run Model Battery Type
Numbers
Charging Current (Max.) 8A 8A  
Charging Voltage 273 VDC ± 1% (Based on 20pcs batteries)
INDICATORS
LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously sounding
PHYSICAL
Standard Model Dimension, DxWxH (mm) 815 x 250 x 826 N/A  
Net Weight (kgs) 164  
Long-run Model Dimension, DxWxH (mm) 592 x 250 x 576 815 x 250 x 826  
Net Weight (kgs) 40 141  
ENVIRONMENT
Humidity 0-95 % RH @ 0- 40°C (Non-condensing)
Noise Level Less than 60dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
*When using internal batteries from 18-19, the unit will de-rate according to the below formula: P = PRating x N/20.
**Derate capacity to 90% of capacity when the output voltage is adjusted to 208VAC.

 